Hi-res PDF file - 6.0 MB

Review home page
Previous Issues
General Information
Mission Statement
Submitting items
The Editors

Page de début Revue canadienne
Dernières parutions
Renseignements généraux
Déclaration de mission
Soumission de détail
Les rédacteurs

IEEE Canada
- home page
- page d'accueil
- committee / comité

IEEE Canadian Review On-line
La revue canadienne de l'IEEE

Spring / Printemps 2012, No. 68

In English
Editorial 
Presidents’ Reports
Canadian Newslog
Regional Coverage: A View from the West
Commentary: Steve Jobs, IEEE and Canada
Field Report: Japan's Recovery by Design
Eng. Management: "Best Of" from the Literature
Conferences 2012/2013 
EPEC-CEE 2012

COMMUNITY NEWS
IEEE-Eta Kappa Nu comes to Region 7
IEEE Canadian Foundation Special Grants
2011 IEEE Canada WIE Prize Presented
Cdn Atlantic Section Boosts IEEE Visibility
Remembrances of Andy Sturton

En français
(en développement)
Feature articles Articles de fonds
Engineering in Medicine and Biology Génie Biomédical

Title/Titre: Modelling Neural Plasticity with Memristors

Authors/Auteurs:
Michael Crupi1, Laxman Pradhan1, Stuart Tozer1
1 Carleton University

Abstract: The goal of this project was to explore the use of memristors for modelling the behaviour of neurons. This paper outlines the approaches used to build a neuromorphic circuit using only passive electronic components, including memristive devices fabricated at Carleton University. Specifically, a model of real-time pattern recognition in the human visual system was used to demonstrate how memristors could be used to simulate memory storage in the brain. Sommaire: Le but de ce projet était d’explorer l’utilisation des memristors afin de modéliser le comportement des neurones. Ce document décrit les approches employées afin d’établir un circuit neuromorphique utilisant seulement des composants électroniques passifs, comprenant les dispositifs memristive fabriqués à l’université Carleton. Spécifiquement, un modèle de reconnaissance des structures en temps réel dans le système visuel humain a été employé pour démontrer comment des memristors pourraient être employés pour simuler le stockage de la mémoire dans le cerveau.
Power Electricité

Title/Titre: Limitations of Distance Protection Associated with the Integration of Renewable Sources

Authors/Auteurs:
Alexandre B. Nassif1, Fenghai Sui1, Miroslav Kostic1
1 Hydro One Networks Inc.

Abstract: Renewable energy sources have received widespread promotion in a drive to offset their polluting counterparts. In Ontario alone over 1.2 GW of renewable energy sources are going to be connected to the transmission grid. Installation of these sources in such dispersed fashion results in system performance degradation, which creates challenges for the transmitter. Power system protection dependability and security can be seriously compromised unless mitigating measures are adopted. Protection and Control planning studies conducted by Hydro One assessed the prevalence of excessively enlarged apparent impedance and current outfeed (current reversal) as being the main culprits of power system protection challenges. A simple criterion is presented to examine current reversal issue in this paper. The paper also presents a case study that encompasses these challenges, along with the solutions that were required for the system to tolerate the new generation. Detailed studies reveal that the required solutions, unanticipated by the proponents as well as by the transmission planners, would be costly. Protection engineers should be aware of these problems and how prevalent they can become as programs such as the Feed- In-Tariff (FIT) program, which in various forms exists in many countries, are adopted. Sommaire: Les sources d’énergie renouvelables ont fait l’objet d’une large promotion afin de se démarquer de leurs contreparties polluantes. Seulement en Ontario plus de 1.2 GW de sources d’énergie renouvelable vont être reliées au réseau électrique. L’installation de ces sources de façon dispersée a comme conséquence la dégradation de la performance du système, qui représente des défis pour la transmission. La fiabilité et la sécurité de la protection du système d’alimentation peuvent être sérieusement compromises à moins que des mesures d’atténuation ne soient adoptées. Les études de planification de la protection et de la commande entreprises par Hydro One ont évalué que les principaux coupables reliés aux défis de protection de système d’alimentation étaient la prédominance d’une impédance apparente excessivement grande et le courant de sortie (inversion de courant). Un critère simple est présenté pour examiner le problème d’inversion du courant dans cet article. L’article présente également une étude de cas qui englobe ces défis, avec les solutions qui ont été exigées afin que le système tolère la nouvelle génération. Les études détaillées indiquent que les solutions exigées, non anticipées par les partisans et par les planificateurs de la transmission, seraient coûteuses. Les ingénieurs en charge de la protection devraient être au courant de ces problèmes et de quelle façon ils peuvent devenir importants pour des programmes tels que le programme Feed-In- Tarif (FIT), qui sous diverses formes existent dans beaucoup de pays et sont adoptés. 
Please consider being a sponsor of the Review. Click here for details.
Considérez devenir un commanditaire de la revue. Cliquez ici pour les détails.


Last update / 2012-06-26 / Dernière mise à jour